<< Click to Display Table of Contents >> Navigation: Components > Multimedia > Lightware MX2 |
This driver is used to connect the Lightware MX2 devices.
Global data points of the component
Name |
Type |
Function |
|---|---|---|
Diagnosis [Text] |
Output |
Error texts are output here. These can be displayed e.g. with the component "Protocol window". Attention: Diagnosis or debug outputs are only provided for the case of an error. Please use only after consultation with the support team! If used, these can considerably impair the performance of the service |
Extended diagnosis |
Input |
(De)Enables the extended debug output. Attention: Diagnosis or Debug - outputs are only provided for the case of an error. Please use only after consultation with the support team! If used, these can significantly affect the performance of the service |
Driver On/Off |
Bidirectional |
(De)Activate the component |
Connection status |
Output |
Shows the connection status as On/Off. |
Send/Delete Queue |
Input |
If switching commands are queued (see below), they can be sent together (for simultaneous switching of the outputs). For this purpose, a TRUE must be sent to this input. If a FALSE is sent to the input, the queue is deleted. |
Dynamic data points of the component (input)
Name |
Type |
Function |
|---|---|---|
Output to all outputs |
Input |
If this input is triggered, the input is output on all outputs. |
Current output |
Folder |
For status output, on which output(s) this input (X) is output. |
Output |
Output |
Number of the output on which this input is displayed (Attention: As an input can be displayed on several outputs, only the first output on which input X is displayed is output here) |
Output 1, ... |
Output |
There is one such data point for each defined output. This data point is used to determine whether input X is output to output Y. |
Select output |
Folder |
to specify the output to which the input is to be output (Attention: Since an input can be output to several outputs, old specifications remain active unless they are explicitly overwritten. If, for example, input 1 is first switched to output 1 and then to output 2, the first circuit on output 1 remains active) |
Output |
Input |
Number of the output on which input X is to be output |
Output (queue) |
Input |
see below |
Output 1, ... |
Input |
If this data point is triggered, input X is (additionally) output to output Y |
Output 1, ... (queue) |
Input |
see below |
Dynamic data points of the component (output)
Name |
Type |
Function |
|---|---|---|
Current input |
Folder |
For status output ,which input is output on this output Y)
|
Entrance |
Output |
Number of the input that is output on this output Y |
Input 1... |
Output |
For each defined input there is one such data point. This data point is used to determine whether input X is output on this output Y. |
Select input |
Folder |
to determine which input should be output to this output Y |
Entrance |
Input |
Number of the input to be output to this output Y |
Input (queue) |
Input |
see below |
Input 1... |
Input |
If this data point is triggered, input X is output on this output Y |
Input 1, ... (queue) |
Input |
see below |
Lock |
Input |
The input (number) currently output on this output can no longer be changed. |
lock status |
Output |
Status, whether the input is blocked or not |
Mute |
Input |
Switches the output (number) silently. |
Mute Status |
Output |
Status, whether the output is silent or not. |
Queue:
If a data point marked with (queue) is used, the respective switchover is not performed directly, but is stored in a queue which is only sent to the device when explicitly triggered (send/delete global data point queue). This is used for simultaneous switching of the outputs to avoid visible delays of the individual outputs.
Properties of the component
Name |
Standard |
Function |
|---|---|---|
number of inputs |
0 |
Specifying the number of media inputs |
number of outputs |
0 |
Specifying the number of media outlets |
Server |
|
The IP address of the Lightware MX2 device is entered here |
Port |
10001 |
Setting for the communication port |
Protocol |
LW2 |
Selection between protocol "LW2" and "LW3" |
Status query Interval |
10 |
Specifies the time interval for the update. |
Driver On/Off |
|
(De)Activate the component. |