<< Click to Display Table of Contents >> Navigation: Components > E-Mobility > DLM distribution data |
This component is used to be able to connect several DLM v2 drivers in order to facilitate an output of the information of the distributions. The data at the outputs refers to the entire distribution in which the station is located, which is called up via "Station name".
Data points of the component
Name |
Type |
Function |
|---|---|---|
Activated |
Output |
Indicates whether the driver is active (on) or not (off). |
Number of charging points (incl. sub-distributions) |
Output |
Shows the number of charging points that are in the "Charging" state. |
Number of charging points |
Output |
Outputs the number of charging points that are in the "Charging" state. |
Diagnosis [Text] |
Output |
Attention: Diagnostic or debug outputs are only intended for use in the event of an error. Please use only after consultation with the support team! If used, they can significantly affect the performance of the service. |
Extended Diagnosis |
Input |
(De)activate advanced diagnostics. |
At least one charging point charges (incl. sub-distribution boards) |
Output |
Is set to "ON" if any connected charging point is in the "charging" state. |
At least one charging point is charging (local) |
Output |
Is set to "ON" if any connected charging point is in the "charging" state. |
Lock |
Bidirectional |
Option to block a specific sub-distribution. The distribution data is then no longer taken into account. |
Current from supply line (L1) |
Output |
Output for the current from the supply line of the sub-distribution. |
Current from supply line (L2) |
Output |
Output for the current from the supply line of the sub-distribution. |
Current from supply line (L3) |
Output |
Output for the current from the supply line of the sub-distribution. |
Current building (L1) |
Output |
Output for the current used by other consumers (without charging currents) of the distribution. |
Current building (L2) |
Output |
Output for the current used by other consumers (without charging currents) of the distribution. |
Current building (L3) |
Output |
Output for the current used by other consumers (without charging currents) of the distribution. |
Measured current (L1) |
Output |
Output for the measured current on the input side of the distribution. |
Measured current (L2) |
Output |
Output for the measured current upstream of the distribution. |
Current measured (L3) |
Output |
Output for the measured current upstream of the distribution. |
Total current (L1) |
Output |
Output for the current of the sub-distribution including other current sources such as PV system. |
Total current (L2) |
Output |
Output for the current of the sub-distribution including further current sources, e.g. PV system. |
Total current (L3) |
Output |
Output for the current of the sub-distribution including further current sources, e.g. PV system. |
Current of charging stations (L1) |
Output |
Output for the measured current of the station. |
Charging station current (L2) |
Output |
Output for the measured current of the station. |
Charging station current (L3) |
Output |
Output for the measured current of the station. |
Current maximum |
Bidirectional |
Output or change possibility of the maximum current of the distribution. |
Current minimum |
Bidirectional |
Output or modification possibility of the minimum current of the distribution system |
Current not used (referred to maximum) |
Output |
Outputs the current that is not used. This refers to the maximum current available for the distribution. |
Current not used (referred to maximum) (L1) |
Output |
Outputs the current that is not used. This refers to the maximum current on L1 that is available for distribution. |
Current not used (referred to maximum) (L2) |
Output |
Outputs the current that is not used. This refers to the maximum current on L2 that is available for distribution. |
Current not used (referred to maximum) (L3) |
Output |
Outputs the current that is not used. This refers to the maximum current on L3 that is available for distribution. |
Current not used (related to allocated current) |
Output |
Outputs the current that is not used by the charging point. It is the difference between the allocated and used current at the charging point. |
Current not used (related to allocated current) (L1) |
Output |
Outputs the current on L1 that is not used by the charge point. It is the difference between the allocated and used current at the charging point. |
Current not used (related to allocated current) (L2) |
Output |
Outputs the current on L2 that is not used by the charge point. It is the difference between the allocated and used current at the charging point. |
Current not used (related to allocated current) (L3) |
Output |
Outputs the current on L3 that is not used by the charge point. It is the difference between the allocated and used current at the charging point. |
Current Reserve |
Bidirectional |
Output or change possibility of the current reserve that is not distributed to the charging points. |
Current used (max) |
Output |
Output of the maximum current used by one of the 3 phases. |
Current assigned |
Output |
Output of the allocated maximum current of the distribution that can be distributed to the charging points. |
Driver On/Off |
Bidirectional |
Driver On or Off. |
Distribution Data (DLM) |
Bidirectional |
Connection to the DLM data point with the same name. |
Distribution name |
Bidirectional |
A character string can be used to select the connected charging stations and output their information. |
Properties of the component
Name |
Standard |
Function |
|---|---|---|
Distribution name |
|
Charging station name |
Driver On/Off |
|
Defines whether the driver is automatically activated at the start of the project. |