<< Click to Display Table of Contents >> Navigation: Components > E-Mobility > OCPP charge station data |
With this invisible server component, linked data points of a charging station can be duplicated with DLM. The assignment of another station is defined via the station name.
Data points of the component
Name |
Type |
Function |
|---|---|---|
Enabled |
Output |
Output whether the charging station is active or not. |
Connection number |
Bidirectional |
Number of the charging point of the wallbox |
Authorisation - active |
Bidirectional |
(De)activate authorisation |
Authorisation - last accepted ID tag |
Output |
Output of the user ID that was last accepted. |
Authorisation - last rejected ID tag |
Output |
Output of the user ID that was last rejected. |
Authorisation - last accepted ID tag |
Output |
Output of the user ID that was last accepted. |
Backend defined |
Output |
If information on the backend is missing, an off signal is output, otherwise an on signal. |
Backend connected |
Output |
If the backend is connected, an ON signal is output. |
Command - (de)activate charging point |
Input |
With an ON signal, the charging point is activated and can be used. |
Command - Start transaction |
Input |
Starts the charging process |
Command - Stop transaction |
Input |
Stops the loading process |
Command - Open interlock |
Input |
Opens the charging socket lock. |
Preferred charging point |
Output |
Due to 1 single-phase charging, some charging points can be marked as "Preferred" (true at this output). This provides a more symmetrical load due to the phase rotation of L1, L2 and L3. |
Diagnosis [Text] |
Output |
Error texts are output here. These can be displayed e.g. with the component"protocol window". Attention: Diagnostic or debug outputs are only intended for use in the event of an error. Please only use them in consultation with the support team! If used, these can considerably impair the performance of the service. |
Query effective charging profile |
Input |
The active charging profile is output as text at the diagnostic output. |
Transfer energy (since reset) |
Output |
Output of the transferred energy since the last reset of the counter reading. |
Energy transmitted (total) |
Bidirectional |
Output of the total transmitted energy |
Transmit energy (transaction) |
Output |
Output of the transmitted energy in the current transaction |
Reset energy |
Input |
Resets the energy counter to 0. |
Extended diagnosis |
Input |
The diagnostic output is extended via an on signal at this input. Attention: Diagnostic or debug outputs are only intended for use in the event of an error. Please use only after consultation with the support team! If used, they can considerably impair the performance of the service. |
Error - Number |
Output |
Error output as number 0-15. Meaning see below. |
Error - Text |
Output |
Output of the error code: 0=ConnectorLockFailure, 1=EVCommunicationError, 2=GroundFailure, 3=HighTemperature, 4=InternalError, 5=LocalListConflict, 6=NoError, 7=OtherError, 8=OverCurrentFailure, 9=OverVoltage, 10=PowerMeterFailure, 11=PowerSwitchFailure, 12=ReaderFailure, 13=ResetFailure, 14=UnderVoltage and 15=WeakSignal. |
In use (OCPP) |
Output |
If the charging station has connected to the OCPP backend, an on signal is output. |
If DC Station |
Output |
If the charging station is a DC charging station, an on signal is output here. |
Calendar editor |
Bidirectional |
Data point for the calendar |
Charging power (requested) |
Bidirectional |
Setting for the desired charging power for the vehicle. |
Charging power plot [filename] |
Output |
Output for the plotter file name |
Charging power plot [URL] |
Output |
Output of the url for display in an image component. |
Charging point data (OCPP - local backend) |
Bidirectional |
Data point for communication with the OCPP component |
Charging current (set) |
Bidirectional |
Possibility to set the charging current in [A] |
Measured value - state of charge |
Output |
Outputs the state of charge in %, if available. |
Measured value - power (grid) |
Output |
Outputs the measured power of the charging station in [W]. |
Measured value - power (car) |
Output |
Outputs the measured power of the vehicle in [W]. |
Measured value - voltage (total vehicle) |
Output |
Outputs the measured voltage of the vehicle in [V] |
Measured value - voltage (L1-N) |
Output |
Outputs the measured voltage in [V] |
Measured value - voltage (L2-N) |
Output |
Outputs the measured voltage in [V] |
Measured value - voltage (L3-N) |
Output |
Outputs the measured voltage in [V] |
Measured value - current (total vehicle) |
Output |
Outputs the measured current in [A] |
Measured value - current (L1) |
Output |
Outputs the measured current in [A] |
Measured value - current (L2) |
Output |
Outputs the measured current in [A] |
Measured value - current (L3) |
Output |
Outputs the measured current in [A] |
Measured value - current (phase maximum) |
Output |
Output of the highest measured current of all phases |
Phase used (L1) |
Output |
If this phase is used, an ON signal is output. Otherwise an OFF signal. |
Phase used (L2) |
Output |
If this phase is used, an ON signal is output. Otherwise an OFF signal. |
Phase used (L3) |
Output |
If this phase is used, an ON signal is output. Otherwise an OFF signal. |
Delete profiles |
Input |
Use any command to delete the profile data for the charging station. |
Serial number |
Output |
Outputs the serial number of the wallbox |
Station - On/Off |
Bidirectional |
(De)activates the charging station |
Station - FW Version |
Output |
Firmware version of the charging station |
Station - ID |
Bidirectional |
ID of the charging station |
Station - Connected |
Output |
Indicates whether the charging station is connected to a vehicle (on) or not (off). |
Station - Restart |
Input |
The charging station is restarted with an on edge. |
Station name |
Bidirectional |
Name of the charging station |
Status - Charging |
Output |
Charging station is in charging mode (on) or not (off) |
Status - Number |
Output |
Status number: 0 = preparing 1 = finished 2 = available 3 = charging 4 = faulted / unavailable 5 = suspended |
Status Number (OCPP) |
Output |
0 = available 1 = preparing 2 = charging 3 = suspended by EVSE 4 = suspended by EV 5 = finished 6 = reserved 7 = unavailable 8 = faulted |
Status - Text |
Output |
Status output (see status number) |
Status - Available |
Output |
If the station is available, an on signal is output. |
Driver On/Off |
Bidirectional |
(De)activating the component |
Properties of the component
Name |
Default |
Function |
|---|---|---|
Station name |
t.b.d |
Name of the charging station, which must match the name in the OCPP. |
Connection number |
1 |
Number of the charging point of the wallbox |
Driver On/Off |
|