<< Click to Display Table of Contents >> Navigation: Components > Manufacturer specific drivers > iKettle |
This invisible driver component is designed to connect iKettle kettle.
Data points of the component
Name |
Type |
Function |
|---|---|---|
Diagnostics [Text] |
Output |
Error texts are output here. These can be displayed e.g. with the component"Protocol window". Attention: Diagnostic or debug outputs are only intended for error cases. Please use only with consultation of the support team! If used, these can considerably impair the performance of the service. |
Dynamic |
Folder |
The data points of the devices are displayed here. There are subfolders per device for the functions. Depending on the device, there may be different functions and display options. |
Extended Diagnosis |
Input |
(De)Activates the extended debug output. Attention: Diagnostic or Debug - Outputs are only intended for error cases. Please use only with consultation of the support team! If used, they can significantly affect the performance of the service. |
Status |
Folder |
This folder contains the data points for the output of the status messages. |
Driver On/Off |
Bidirectional |
(De)Activate the component |
Interrupt |
Input |
Any signal is used to interrupt the heating process. |
Boil water |
Input |
Any signal is used to start the heating process to boil the water. |
Heat water (temperature + trigger) |
Input |
If a temperature is entered, the heating process starts up to the entered temperature. |
Heat water (heating time minutes) |
Input |
Time preset in minutes, for keeping the water warm. |
Properties of the component
Name |
Default |
Function |
|---|---|---|
IP |
|
The IP address of the iKettle kettle must be entered here. |
Port |
2081 |
Communication port of the iKettle. |
Status Readout interval [s] |
5 |
Time interval in seconds for status update. |
Water Sensor Raw Value Minimum |
2048 |
Sensor value when no water is filled in. The value must be determined in order to calculate the fill level. |
Water sensor raw value maximum |
4096 |
Sensor value when the water is filled to the maximum. The value must be determined in order to calculate the fill level. |
Driver On/Off |
|
(Dis)enable the component. |