AVM home automation

<< Click to Display Table of Contents >>

Navigation:  Components > Manufacturer specific drivers >

AVM home automation

The AVM driver is an invisible server component with the possibility to control the connection of the Fritz Home Automation devices. To use this driver, the AVM devices must be taught-in on the Fritz!Box.

 

Data points of the component

Name

Type

Function

Diagnosis [Text]

Output

Attention: Diagnostic or debug outputs are only intended for use in the event of an error. Please use only after consultation with the support team! If used, these can significantly affect the performance of the service.

Dynamic

Folder

Contains the data points of the connected devices. These vary depending on the type of device.

Advanced Diagnostics

Input

Extends the output at the diagnosis data point to include further information. Attention: Diagnostic or debug outputs are only intended for use in the event of an error. Please use only after consultation with the support team! If used, these can significantly affect the performance of the service.

Driver On/Off

Bidirectional

Turn driver on or off.

Connection status

Output

If the connection to the FritzBox was established, an ON signal is output. If the connection is interrupted, an OFF signal is output.

 

Properties of the component

Name

Standard

Function

Connection

 

Enter the IP address of the device on which the AVM Smart Home devices are registered and the account data. The update interval is set in seconds.

Channels

 

In the Channel Editor, the Smart Home devices are imported from the Fritz!Box and displayed.

Driver On/Off

OFF

Defines whether the driver is automatically activated at the start of the project.

 

Note:

The feedback for colour temperature is only output if it is also in Colortemp mode. The same applies to saturation.

Current colour mode: current_mode: string 1(HueSaturation), 4 (colour temperature) or ""(empty → unknown)

 

Supported functions:

AVM Button

AVM radiator controller

AVM energy meter

Temperature sensor

AVM switchable socket

Device/socket/lamp/actuator that can be switched on/off

Device with adjustable dimming, height or level

Lamp with adjustable colour/colour temperature

Roller shutter (blind) - up, down, stop and level 0% to 100%