PJLink

<< Click to Display Table of Contents >>

Navigation:  Components > Multimedia >

PJLink

This driver is used to connect beamers that support PJLink communication.

 

Data points of the component

Name

Type

Function

Commands

Folder

This folder contains all data points for controlling the beamer. To select a media input, a number must be sent to the corresponding data point. This refers to the selection of the source if several identical inputs are available (HDMI-1, HDMI-2, ...).

Diagnosis [Text]

Output

Error texts are output here. These can be displayed e.g. with the component "Protocol window". Attention: Diagnosis or debug outputs are only provided for the case of an error. Please use only after consultation with the support team! If used, these can considerably impair the performance of the service.

Extended diagnosis

Input

(De)Enables the extended debug output. Attention: Diagnosis or Debug - outputs are only provided for the case of error. Please use only after consultation with the support team! If used, these can significantly affect the performance of the service.

Device accessible

Output

Shows whether commands can be sent to the device (true) or not (false).

Status

Folder

The status messages of the device are output here.

Update status

Input

The update is triggered by any input.

Driver On/Off

Bidirectional

(De)Activate the component.

UDP Receiver Status

Output

Shows whether a UDP connection exists (true) or not (false).

Cyclic status request

Bidirectional

(De)Activates the cyclic status request.

 

 

Properties of the component

Name

Standard

Function

Device IP

0.0.0.0

Enter the device IP address of the beamer.

Class 2 Device

 

Class 1 devices can process fewer commands than class 2 devices (see manufacturer data).

Password

 

If a device password has been set up, the password must be entered here.

Activate UDP receiver

X

(De)Activates the UDP connection. Depending on the device, status messages are sent cyclically from the beamer. If this is the case, this option must be selected.

Local IP

0.0.0.0

Enter the EisBaer server IP address.

Cyclic status request

X

Allows cyclical updating at the set interval.

Status check Interval [s]

10

Time setting for the cyclic update in seconds.

Driver On/Off

 

(De)Activate the component.