ModEye26 – Modbus Discovery & Decoder (annual license)

ModEye26 – Modbus Discovery & Decoder (annual license)

Order number: AM-SW-MODEYE26

€ 70,21

incl. 19% GST., plus Delivery costs (0 kg)

Scan Modbus. Read it in every decoding. Annual license with a 12-month term, single workstation, updates and e-mail support included.

Add to cart

Description

ModEye26 scans any Modbus device and shows every value instantly in all possible decodings at once – big/little endian, byte swap, word swap, INT & Float. You spot the right interpretation at a glance, no guesswork.

The tool for the whole industry – KNX integrators, PV, charging stations or building control. And for EisBaer users, the recognised device moves straight into the EisBaer profile with one click.

Features

  • All eight Modbus transports: Modbus TCP and UDP, Modbus RTU and ASCII over the serial port, plus RTU and ASCII over TCP or UDP – so every serial server and RS485 Ethernet gateway as well. TCP connections optionally TLS-encrypted (Modbus/TCP Security).
  • Bus scan & discovery: searches IP ranges and the serial bus for unit IDs, lists found devices and detects responding registers automatically.
  • Decoder – every decoding at once: the same raw value in 14 byte and word orders, as INT16/32/64, UINT, Float32/64, hex or ASCII text. You instantly see which interpretation yields a sensible value – one click transfers it into the Monitor.
  • 619 ready-made device profiles for 238 manufacturers – among them ABB, Schneider, Siemens, Janitza, Carlo Gavazzi, Hager, Socomec, SMA and Belimo. Load, connect, done.
  • Vendor-independent: whether BMS, PLC, energy meter or inverter – ModEye talks to any Modbus device.
  • Export & templates: save the configuration as .modbus (EisBaer SCADA XML), .xml or .csv and reload it any time as a device template.
  • Master, slave & monitor: read and write registers manually, poll values continuously or run ModEye itself as a Modbus device to test a control station without real hardware.
  • Secure & offline: runs entirely locally in the plant network. No cloud, no telemetry – and the trace/log shows every telegram for troubleshooting.

License and delivery

  • Annual license with a 12-month term
  • Single-workstation license, valid for one seat
  • All features without trial limit, EisBaer import and export included
  • Updates included
  • Support by e-mail
  • For Windows (64-bit)
  • You receive the license code by e-mail as soon as your payment has arrived. A free trial license is available directly from within the application.

Technical data

  • Transports: Modbus TCP, Modbus UDP, Modbus RTU (serial), Modbus ASCII (serial), RTU over TCP, ASCII over TCP, RTU over UDP, ASCII over UDP
  • Encryption: Modbus/TCP Security (TLS), for TCP connections
  • Modes: master, slave, monitor, bus scan, network scan, decoder, trace/log
  • Function codes: 01, 02, 03, 04, 05, 06, 08, 11, 15, 16, 17, 22, 23 and 43 (device identification)
  • Data areas: coils, discrete inputs, holding registers, input registers
  • Data types: bool, INT16/32/64, UINT16/32/64, Float32/64, hex, ASCII string
  • Byte and word orders: 14 variants – AB and BA (16-bit), ABCD, BADC, CDAB and DCBA (32-bit) plus all eight 64-bit combinations
  • Device profiles: 619 templates included, for 238 manufacturers
  • Serial parameters: COM port, baud rate, parity (none/even/odd), stop bits
  • Export and import: .modbus (EisBaer SCADA XML), .xml, .csv
  • Operating system: Windows, 64-bit
  • License: annual license, 12-month term, single workstation, hardware-bound