Data points of the component
Name |
Type |
function |
|---|---|---|
Single request |
Input |
Triggers a single query from the CMS system |
Cyclic request |
Bidirectional |
Starts / stops the cyclical data query. |
Cyclic request - delay [s] |
Bidirectional |
Setting the pause time between 2 queries in seconds |
Detailed diagnosis |
Bidirectional |
(De)Activates the extended debug output. Attention: Diagnostics or debug outputs are only intended for use in the event of an error. Please only use them after consulting the support team! If used, these can significantly impair the performance of the service |
Diagnosis [Text] |
Output |
Attention: Diagnostics or debug outputs are only intended for errors. Please only use after consulting the support team! These can significantly affect the performance of the service when used. |
Reset energy groups |
Input |
Resetting the energy values. |
Max values reading interval [min] |
Input |
Setting the reading interval in minutes for the voltage peaks |
Reset min / max values |
Input |
Reset the min / max values for each channel. |
Voltage L1-L2 [V] |
Input |
Input for the measured voltage on the corresponding path. |
Voltage L1-N [V] |
Input |
Input for the measured voltage on the corresponding path. |
Voltage L2-L3 [V] |
Input |
Input for the measured voltage on the corresponding path. |
Voltage L2-N [V] |
Input |
Input for the measured voltage on the corresponding path. |
Voltage L3-L1 [V] |
Input |
Input for the measured voltage on the corresponding path. |
Voltage L3-N [V] |
Input |
Input for the measured voltage on the corresponding path. |
Strom Sum L1 [A] |
Output |
Returns the total current of the phase |
Strom Sum L2 [A] |
Output |
Returns the total current of the phase |
Strom Sum L3 [A] |
Output |
Returns the total current of the phase |
Strom Sum N [A] |
Output |
Outputs the total current of the neutral conductor |
Connection state |
Output |
Displays whether the connection is established (true) or not (false). |
Trigger holding |
Input |
(De) Activate value storage. |
Properties
Name |
Standard |
function |
|---|---|---|
Channels |
0 |
One channel can be created here for each sensor. |
Connection |
Serial... |
Setup for communication (Modbus Serial / Modbus TCP) |
Cyclic request - delay |
1 |
Setting the pause time between 2 queries in seconds |
Cyclic request - Autostart |
|
Starts / stops the cyclical data query. |
Voltage L1-N [V] |
230 |
Specify the voltage for the calculation if there are no measured values. |
Voltage L2-N [V] |
230 |
Specify the voltage for the calculation if there are no measured values. |
Voltage L3-N [V] |
230 |
Specify the voltage for the calculation if there are no measured values. |
Voltage L1-L2 [V] |
400 |
Specify the voltage for the calculation if there are no measured values. |
Voltage L2-L3 [V] |
400 |
Specify the voltage for the calculation if there are no measured values. |
Voltage L3-L1 [V] |
400 |
Specify the voltage for the calculation if there are no measured values. |
Max-Value read interval [min] |
1 |
Readout interval in minutes for the voltage peaks |
Use old library |
|
This option realises the processing of Modbus data via a newer API. |
Output NULL to network in the event of an error |
X |
Registers that cannot be read or if there is another error, the outputs are set to NULL. This clears the value displays. |
Driver On/Off |
|
(De) Activate value storage. |