<< Click to Display Table of Contents >> Navigation: Components > Manufacturer specific drivers > Nanoleaf |
The RGBW luminaires from Nanoleaf can be controlled with this driver.
Data points of the component
Name |
Type |
Function |
|---|---|---|
Command |
Folder |
These data points can be used to centrally control the entire installation. |
Blink Interval [100ms] |
Bidirectional |
Setting option for the blinking speed of the panels. |
Diagnosis [Text] |
Output |
Error texts are output here. These can be displayed, for example, with the"Protocol window" component. Attention: Diagnostic or debug outputs are only intended for use in the event of an error. Please only use them in consultation with the support team! If used, these can considerably impair the performance of the service. |
Dynamic |
Folder |
This is where the data points for the imported effects and the panels are created. The effects are selected via an on signal. The individual panels have data points for the RGB values (0-255) and flashing (on/off). Note: The colour white is automatically generated by the panels and has no data point of its own. |
Advanced Diagnostics |
Input |
(De)Activates the extended debug output. Caution: Diagnostic or debug outputs are only intended for use in the event of an error. Please use only after consultation with the support team! If used, they can significantly affect the performance of the service. |
Info |
Folder |
Information about the Nanoleaf system is output to the data points in this folder. |
Status |
Folder |
This folder contains the data points for outputting the status messages of the entire installation. |
Driver On/Off |
Bidirectional |
(De)activates the component at service start. |
Connection status |
Output |
If there is a connection to the Nanoleaf, an on signal is output. If the connection is interrupted, an off signal is output (after the set time-out time). |
Properties of the component
Name |
Standard |
Function |
|---|---|---|
Connection |
|
The IP address of the Nanoleaf is entered here. To establish the connection, it must be authorised. Pairing mode must be active for this. |
Effects |
|
Taught-in effects can be imported here. |
Panels |
|
All connected LED panels are imported here with their name, ID and position. The name can be freely defined. The position information can help to determine where a panel is actually located so that it can be controlled directly. |
Blink Interval [100ms] |
5 |
Setting option for the blinking speed of the panels. |
Driver On/Off |
|